The MEC II-series pumps have an automatic protection system. So, for example, if a vane breaks, the rotor and rotor housing can be protected by the rotor—including the flange mountings—being pushed downwards
The operating time at -0.95 bar lasts from 8 minutes (standard) up to a maximum of 15 minutes. Continuous operation is permissible at -0.6 bar.
MEC II-series pumps are supplied with long-life (heat-resistant) vanes as standard
MEC II-series pumps feature a temperature meter to enable the temperature to be read during operation
A maintenance hatch can be used to determine the wear condition of the vanes, indicating when the vanes need to be replaced
Each pump is subjected to a final check in the factory, in which the vacuum, compression and lubrication are tested, among other factors
A test report relating to the serial number is drawn up for each pump
Drive Type - PTO 540rpm
Max Vacuum - 0.95 Bar
Max Relative Pressure - 1.5 BAR
Power requirement for max pressure - 36kW
Power requiremnet for max vacuum - 17kW
Diameter of Hose Connection - 80mm
Safety valve connection diameter - 2inch
Depression Valve Connection Diameter - 1-1/2inch
Total Length - 670mm
Total width - 390mm
Height - 605mm
Weight - 145kg